| Model |
Temperature Scope |
Internal Size mm W*H*D |
External Size mm W*H*D |
power |
| ST-45 |
Ambient temperature
+10
│
200 (300 ) |
450*450*450 |
1070*1435*690 |
AC220V |
| ST-60 |
600*600*600 |
1220*1585*840 |
| ST-75 |
750*750*750 |
1370*1735*990 |
| Temperature proportion |
1% |
| Temperature control |
PID automatic arithmetic microcomputer
temperature controller |
| Timing device |
0~999 min. |
| Circulation Fashion |
Compelled Fan Circulation Fashion |
| Testing frame |
Speed 10rpm double level testing frame
|
| Air replacement rate |
0~200 times/Hr adjustable with air
replacement adjustment button and digital power meter for exchange
calculation of power loss and air replacement standard |
| Internal material |
SUS#304 Stainless steel |
| External material |
Zinc galvanizing steel board roasted
paint coating in conformity with ASTM Regulation |
| ASTM Regulation |
Thermal
Shock tester
This tester measures the reaction,
variation and destruction test of electronics, chemical, plastic, metal,
military objects and other components under the rapid change between high
temperature and low temperature.
The design is divided into hot storage, test chamber and cool storage.
Objects to be tested stands still in the test chamber, with 2-zone or 3-zone
measurement
functions.
Feature:
- Touch type microcomputer controller, easy-to-use and easy-to-learn, clear
display
- Selective 2-zone and 3-zone shock test
- Programmable recycle and defrost times
- Operating status display and curve
- Abnormal and fault point indicating instruction
- Efficient binary refrigeration set
- American & European compressor set, low operation noise
- Multi-protection device
Feature
| Model |
FT-40 |
FT-50 |
FT-60 |
LT-40 |
LT-50 |
LT-60 |
TT-40 |
TT-50 |
TT-60 |
| Method |
tested object still type, cool & hot
wind switching method zone 2or zone 3 |
| Chamber Temperature |
-35
~ 0 / 60
~150 |
-55 ~
10 / 60 ~150
|
-65 ~
10 / 60 ~150 |
| Temperature precision |
2  |
| High temperature type temperature |
80 200 |
80 200 |
80
200 |
| Low temperature type temperature
|
-35 ~-10 |
-60 ~-10 |
-70 ~-10 |
| Temperature rising time |
30 |
40 |
40 |
30 |
40 |
40 |
30 |
40 |
40 |
| Temperature falling time
|
60 |
70 |
80 |
60 |
70 |
80 |
60 |
70 |
80 |
| Temperature recovery tim |
5~10 minutes |
| Chamber dimension |
35 |
50 |
60 |
35 |
50 |
60 |
35 |
50 |
60 |
| 35 |
40 |
50 |
35 |
40 |
50 |
35 |
40 |
50 |
| 40 |
40 |
50 |
40 |
40 |
50 |
40 |
40 |
50 |
| External Size |
155 |
170 |
180 |
155 |
170 |
180 |
155 |
170 |
180 |
| 195 |
200 |
220 |
195 |
200 |
220 |
195 |
200 |
220 |
| 140 |
150 |
165 |
140 |
150 |
165 |
140 |
150 |
165 |
| Testing objects Weight |
2.2 |
5 |
7.5 |
2.5 |
5 |
7.5 |
2.5 |
5 |
7.5 |
| Refrigeration system |
Simoleon type |
binary type |
binary type |
| Condensation Method |
Air-cooled type |
Water-cooled type |
| HFC Refrigerant environmental
protection |
Refrigerant
HFC |
| Control Method |
Microcomputer programmable
control +PID+SSR |
| Internal and external material
|
SUS304#
Stainless steel |
| Safety device |
Compressor overload protective
device, control system overload protection, high & low voltage
protective switch |
|